SECA, workplace safety and environmental support
Home/Air Monitoring

Manganese: three limits, and why the OSHA ceiling is the weakest

This page explains what the rules and common practice call for. Every site is different, and what a survey or a filing needs at your facility is something we work out with you after we see it.

OSHA has no 8-hour time-weighted average (TWA) limit for manganese. The permissible exposure limit (PEL) is instead a ceiling limit of 5 milligrams per cubic meter of air (mg/m³), a level that must not be exceeded at any time. It applies to total particulate, meaning all airborne dust and fume with no particle-size selection. It is listed in Table Z-1, OSHA's general table of air contaminant limits, and has been carried forward from 1971.

The structure of the limit matters more than the number. A welding shop can run 8 hours a day at levels every current health-based limit treats as too high and never once exceed the OSHA ceiling, because the ceiling does not measure the thing that causes the harm.

That harm is neurological: manganism produces symptoms like those of Parkinson's disease, and they do not reverse. The damage is slow and cumulative, and a ceiling on a single moment is a poor tool for a hazard that builds up over time.

Manganese appears only in Table Z-1, and OSHA has no substance-specific standard for it, so there is no action level and no required monitoring schedule. That is not the same as having no obligation.

Where we find it

You do not have to work this out alone.Ron Fleming has done this work himself since 1993. We come to your plant, sample the air, and tell you what you need and what you do not. See if we are the right fit. No cost.·More about air monitoring surveys

Exposure limits

Two other organizations publish manganese limits, and both are recommendations. NIOSH sets a recommended exposure limit (REL). ACGIH is the professional body that publishes the threshold limit values (TLVs).

Source Limit Averaging time Particle size fraction
OSHA 5 mg/m³ ceiling limit. OSHA has no 8-hour TWA PEL Ceiling Total particulate
NIOSH REL 1 mg/m³ TWA · 3 mg/m³ short-term exposure limit (STEL) TWA over up to 10 hours / short-term -
ACGIH TLV 0.02 mg/m³ 8-hour TWA Respirable (the finest particles)
ACGIH TLV 0.1 mg/m³ 8-hour TWA Inhalable (all particles a person can breathe in)

The gap, stated honestly

You will often see the gap quoted as 250 to 1, which sets OSHA's 5 mg/m³ against ACGIH's 0.02 mg/m³. The arithmetic is right, but the comparison needs a caveat.

Those two numbers do not measure the same thing. One is a ceiling on total particulate at any single moment, set in 1971. The other is an 8-hour TWA of the respirable fraction, the particles fine enough to reach deep into the lungs. Comparing the two directly is like comparing a speed limit to a fuel economy figure.

So take the closest match available. ACGIH also has an inhalable TLV of 0.1 mg/m³, which covers all the particles a person can breathe in through the nose or mouth. Set that against OSHA's 5 mg/m³ and the gap is still 50-fold.

The NIOSH REL sits between them, at 1 mg/m³ as a full-shift TWA. That is 5 times below the OSHA number and 10 times above the ACGIH inhalable value.

However you frame it, the conclusion holds: the federal limit that OSHA can enforce is far above what every current health-based limit treats as protective. The gap is not small, and two practical consequences follow.

It is the clearest General Duty Clause risk in a weld shop. Under the General Duty Clause, OSHA can cite a recognized hazard that has a feasible means of abatement, even where no PEL is exceeded. Here NIOSH and ACGIH both agree on a documented gap of this size, which is about as strong a record of a “recognized hazard” as exists.

It also has to be planned before the site visit. Comparing a result to the ACGIH TLVs takes more than changing the number in the report.

Choosing which limits you want to be evaluated against is therefore also a choice of sampling equipment, and that choice is made before anyone arrives on site.

→ OSHA PELs compared with ACGIH TLVs

How we sample for it

Sampling media Mixed cellulose ester filter, 0.8 µm, 25 mm or 37 mm
Analytical method OSHA ID-125G (metals analysis by ICP)
Pump flow rate 2 liters per minute (L/min)
Sample type Personal sample in the worker's breathing zone, for the full shift

OSHA method ID-125G allows the 25-mm cassette where space is tight. That is what makes sampling inside the welding helmet practical. A 37-mm cassette clipped inside a helmet is bulky, and welders move it, tilt it, or route the tubing in a way that changes what it collects.

The 25-mm cassette is the difference between a sample the welder tolerates for 8 hours and one you have to void. It is a permitted option, not the preferred one, and outside the helmet 37 mm is the normal choice.

Sampling inside the helmet and sampling outside it answer different questions. An outside sample shows the exposure in the workplace, while an inside sample shows what the welder actually breathes and is the right measurement when you are evaluating a powered air-purifying respirator. A report should state which one was done.

Gravimetric dust (dust by weight) is a separate sample. Manganese is collected on a 0.8-µm mixed cellulose ester filter and analyzed by ICP under method ID-125G.

Total or respirable dust by weight runs under a different OSHA method, PV2121, which uses a pre-weighed, low-ash 37-mm PVC filter. Total dust is sampled with no cyclone, while respirable dust is sampled behind a 10-mm nylon Dorr-Oliver cyclone at 1.7 L/min.

A PVC filter used for gravimetric analysis does not give a manganese result, and a cellulose ester filter analyzed for metals does not give a weight.

The same logic applies to particle size. The OSHA ceiling is for manganese in total particulate, which is collected on a closed-face cassette with no size selection. The 0.02 mg/m³ ACGIH TLV is for manganese in the respirable fraction, which requires a cyclone ahead of the filter. A cyclone removes the very material the total figure is meant to include.

To evaluate one welder against both limits, you need two sampling trains on one person, because one cassette cannot give both.

→ Welding fume air monitoring

What you do with a manganese result

There is no deadline for notifying workers of their results, because no manganese standard exists to set one. What you do get is this:

A survey planned for it can show you where you stand against all three limits. What you do about the gap is a business decision, and it should be made with the numbers in front of you, not avoided by declining to collect them.

Plan a manganese and welding fume survey

Ron Fleming has done this work himself since 1993. You talk directly to the person who does the job. No account managers. No call center. Our prices are well below the competition. Tell us what is going on and we will send a written scope of work and a price, at no cost.

Talk with us. No cost.

References

The regulations and standards behind this page, with links to the official text, so you can check the source yourself.